Home / Rigging / Load Weighing Equipment / Straightpoint WireLink Plus Tension Load Cell
Straightpoint WireLink Plus Tension Load Cell
Straightpoint WireLink Plus Tension Load Cell

Secure Payment Transaction Guarantee

Choose Rapid Shipping at Checkout

24/7 U.S. Based Customer Service Help
Quick Overview:
- Up to 300,000kg capacity
- 10 Meter cable as standard
- Non-indicating for use with handheld plus
Customers Also Bought
Excluding a built-in display, Straightpoint's WireLink Plus is similar to the very popular RadioLink and LoadLink Plus digital dynamometer tension load cells.
A non-indicating load link is designed to be used in conjunction with a cabled handheld plus digital display (HHP), desktop controller PC software (DCP10M), and can ever be connected to a wireless transmitter to form part of a wireless system in combination with specific computer software - please contact our sales team for more information on the DCP10M load monitoring software.
Manufactured from aerospace-grade aluminum, the WireLink Plus has an advanced internal design structure that provides operators with an unmatched strength-to-weight ratio.
This range of cabled (wired) load links are extremely lightweight, easy to handle and operate, hence why they are trusted throughout the world across an extensive range of industries for lifting and pulling activities, as well as proof and structural load testing with capacities ranging from 1 tonne right up to 300 tonnes.
Supplied with a 10 meter cable as standard, the WireLink Plus, however, can also be supplied with lengths up to 1,500m depending on output format.
Analogue output options include:
- 3 Wire 0-10v
- 3 Wire 0-5v
- 4 Wire +/- 10v
- 3 Wire 4-20mA
- 2 Wire 4-20mA
- Constructed of lightweight aerospace grade aluminium
- Available in capacities ranging from 1 - 300 tonnes
- High accuracy
- Multiple output options include mV/V, analogue out, ASCII, MODBUS RTU and CAN-BUS
- Available in IP68 Environmental protection
- Options for subsea available
Model | Capacity (kg) | Weight (kg) | Saftey Factor | Operating Temperature | Protection | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | F (mm) | G (mm) | Crosby Shackle Size | Loading Pin Diameter (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
WLP1T | 1000 | 1.4 | 12:1 | -10˚C Up to 50˚C | IP67 | 204 | 43 | 101 | 146 | 24.5 | 48 | 19 | G2130 | 19 |
WLP2T5 | 2500 | 1.4 | 5:1 | -10˚C Up to 50˚C | IP67 | 204 | 43 | 101 | 146 | 24.5 | 48 | 19 | G2130 | 19 |
WLP5T | 5000 | 2 | 5:1 | -10˚C Up to 50˚C | IP67 | 249 | 43 | 101 | 165 | 38 | 66 | 32 | G2130 | 25 |
WLP12T | 12,000 | 3.2 | 5:1 | -10˚C Up to 50˚C | IP67 | 305 | 47 | 101 | 193 | 47.5 | G2130 | 35 | ||
WLP25T | 25,000 | 5 | 5:1 | -10˚C Up to 50˚C | IP67 | 340 | 60 | 115 | 215 | 55 | G2130 | 51 | ||
WLP35T | 35,000 | 8.6 | 5:1 | -10˚C Up to 50˚C | IP67 | 393 | 75 | 126 | 225 | 60 | G2130 | 57 | ||
WLP50T | 50,000 | 11.5 | 5:1 | -10˚C Up to 50˚C | IP67 | 424 | 75 | 163 | 230 | 76 | G2140 | 57 | ||
WLP75T | 75,000 | 16 | 5:1 | -10˚C Up to 50˚C | IP67 | 470 | 75 | 202 | 260 | 76 | G2140 | 70 | ||
WLP100T | 100,000 | 34 | 5:1 | -10˚C Up to 50˚C | IP67 | 608 | 99 |